Module Not Detected

CoreBAR doesn't recognize an attached module.

🔍

Module Not Recognized by CoreBAR

Solved

You've attached a module via QuantumLink™, but CoreBAR doesn't show it in the interface. The module may appear to have power but isn't functional.

Solution

  • Check the magnetic connection: Modules should snap firmly into place. You should hear a click
  • Reattach the module: Detach and reattach it to ensure a clean connection
  • Check for debris: Clean the pogo pins on both CoreBAR and the module with a soft, dry cloth
  • Check the orientation: Make sure the module is oriented correctly — the pogo pins should align with the contacts
  • Check the module limit: CoreBAR supports up to 15 modules total (including up to 3 VivoCubes)
  • Restart CoreBAR: Sometimes a simple power cycle resolves detection issues
  • Check Ultra Workspace: In Ultra Workspace, go to Modules and click "Add" to see if the module appears
Note: When a module is first attached, CoreBAR should show a notification. If you don't see this, the module isn't being detected at the hardware level. Check the physical connection first.

Magnetic Connection Loose

Modules don't stay firmly attached to CoreBAR.

🧲

Magnetic Connection Feels Loose

Solved

Modules don't snap into place securely, or they fall off easily. The magnetic connection feels weaker than expected.

Solution

  • Check the pogo pins: Inspect both CoreBAR and module contacts for any debris or damage
  • Clean the contacts: Use a soft, dry cloth to gently clean the pogo pins and magnetic contacts
  • Check module alignment: Make sure the module is aligned correctly with the magnetic guides on CoreBAR
  • Check for magnetic obstruction: Keep the module away from other magnetic objects that could interfere
  • Try a different module: If other modules attach securely, the issue may be with the specific module
  • Check for physical damage: Inspect both CoreBAR and module for any visible damage
Tip: The QuantumLink™ connection uses N52 magnets. They are strong but can be weakened by physical damage or debris. Always store modules in a clean, dry environment.

LED Indicator Flashing

Module's LED indicator is flashing or behaving abnormally.

💡

Module Indicator Light Flashing Abnormally

Solved

The LED indicator on your module is flashing in an unusual pattern, or it's not responding to inputs as expected.

Solution

  • Check the LED pattern: A slow, steady flash typically indicates normal operation. Fast flashing may indicate an error condition
  • Check power delivery: If you have more than 3 modules attached, use the DC 12V power adapter for stable power
  • Check module configuration: In Ultra Workspace, verify the module is properly configured
  • Check for firmware updates: Some modules may require a firmware update via Ultra Workspace
  • Restart CoreBAR: A power cycle can reset the module's LED state
  • Reattach the module: Detach and reattach the module to reset its internal state
Note: Different modules have different LED behaviors. Check the specific module's manual for details on LED patterns and what they indicate.